true
{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
XenMatrix™ Greffes biologiques de hernie Greffon chirurgical XenMatrix™

Greffon chirurgical XenMatrix™, carré, 11,8 po x 11,8 po (30 cm x 30 cm)

Présentation

Confidence Reinforced

XenMatrix™ Grafts are created using the patented AquaPure™ Process which effectively removes cells while maintaining the structure and strength of the graft. The resulting open collagen scaffold allows early cellular infiltration and revascularization without a significant loss of strength during the early healing process as demonstrated in preclinical studies.1

true
Caractéristiques et avantages
Notre Histoire
false
Spécification

GTIN - null

00801741074400

1


Quantité

1/cs


Dimensions

Carré de 11,8" x 11,8" (30 cm x 30 cm)

GTIN

GTIN - null 00801741074400 1

Emballage

Quantité 1/cs

Spécifications du produit

Dimensions Carré de 11,8" x 11,8" (30 cm x 30 cm)
Ressources
Questions fréquentes
false
Produits connexes
Produits connexes non disponibles
Plaintes concernant un produit
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Élements à prendre en compte

Si vous êtes un patient ou un utilisateur final, vous pouvez nous contacter vous-même, ou vous pouvez demander à votre soignant ou à votre médecin de le faire pour vous. Pour nous aider à traiter vos
informations rapidement et efficacement, veuillez contacter notre équipe chargée des réclamations clients.

Pour faciliter notre enquête, veuillez inclure les informations suivantes dans votre rapport:


  • Nom du produit et/ou numéro de catalogue
  • Numéro de lot ou numéro de série
  • Blessures et/ou préjudices?
  • Quel est le problème que vous avez rencontré?
  • Est-ce-que l'échantillon réel ou le représentant de l'échantillon est disponible? (Si possible, veuillez envoyer l'échantillon concerné)
  • Nom et numéro de téléphone de la personne à contacter
Références

1. Preclinical data on file, results may not correlate to clinical performance

2. Deeken CR, Eliason B, Pichert M, Grant S, Frisella M, Matthews B. Differentiation of Biologic Scaffold Materials Through Physiomechanical, Thermal and Enzymatic Degradation Techniques. Ann Surg 2012. Mar; 255(3):595-604.

Indications

Intended for implantation to reinforce soft tissue where weakness exists and for surgical repair of damaged or ruptured soft tissue, including: abdominal plastic and reconstructive surgery; muscle flap reinforcement; hernia repair including abdominal, inguinal, femoral, diaphragmatic, scrotal, umbilical, and incisional hernias.

Contraindications

XenMatrix™Surgical Graft should not be used on patients with known sensitivity to porcine products. Not for reconstruction of cardiovascular defects. Not for reconstruction of central nervous system or peripheral nervous system defects. Use of this product in applications other than those indicated has the potential for serious complications.

Warnings

If an infection develops, it should be treated aggressively. An allergic reaction, which is unrelated to other therapy, is an indication to consider removal of XenMatrix™ Surgical Graft.

Precautions

Place device in maximum possible contact with healthy, well-vascularized tissue to promote cell ingrowth and tissue remodeling. When unable to close skin over the XenMatrix™ Surgical Graft, ensure that the implant remains moist. Avoid drying of the implant through “continued suction devices” as this may negatively impact the performance of the implant. Only physicians qualified in the appropriate surgical techniques should use this surgical graft. The surgeon should thoroughly understand the surgical procedure and the performance characteristics of the surgical graft.

Adverse Reactions

Potential complications with the use of any prosthesis may include, but are not limited to, allergy, seroma, infection, inflammation, adhesion, fistula formation, hematoma and recurrence of tissue defect.

Please consult package insert for more detailed safety information and instructions for use.

true
true