true
Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.847.2220

BD VeloCath™ Intravascular Catheter

Specifically indicated for accessing jugular veins

Contact Us
IF_VeloCath_202632045_DSC_5031_P.jpg
IF_VeloCath_202632049_DSC_5089_P.png
IF_VeloCath_202632043_DSC_5130_P.jpg
Loading

About

false

Features and Benefits

Accutip™ Nitinol Guidewire

Upper Copy1 field in Tab Coiled tip guidewire engineered to navigate tortuous vessel anatomy for atraumatic delivery. Designed to minimize the need for unnecessary needle advancement that may lead to vessel damage and complications.

2.Power injectable

Power injectable

With contrast media up to 6 mL/sec at 300 PSI.

Blood control valve

Designed to reduce blood flow into the catheter hub after insertion until a secure Luer connection is made. 

Air embolism is a potentially fatal complication associated with acute central line insertion procedures. The blood control valve is designed to reduce the risk of an air embolism.

Built-in needlestick safety

Spring retracts at the push of a button.
5.Instaflash™ Needle Technology

Instaflash™ Needle Technology

Allows for the immediate visual confirmation of vessel entry.

Flow rates

The BD VeloCath IV Catheter is designed to deliver fluids rapidly, allowing up to 3,720 mL/hr.

Improved flow actuator

Redesigned to improve flushability of catheter hub.

Accuflash™ Secondary Chamber

Designed to give clinicians an additional indicator of successful cannulation/vascular access.

Textured grip housing

Designed for device control placement.

Echogenic guidewire design

Echogenicity of the guidewire is designed to aid in insertion when using ultrasound devices.

An alternative to traditional PIVS and CVCs

According to BD market research1, emergency clinicians estimate that about 20% of acute CVCs are placed unnecessarily in the Emergency Department, simply because peripheral IV access could not be attained first. BD VeloCath™ IV Catheter can be a faster, less invasive option in many emergent situations.

Designed for difficult vascular access

Over 33% of adult patients have difficult venous access (DVA)2. In many of these patients, peripheral venous access is difficult or impossible to obtain using conventional methods, presenting a unique challenge to clinicians. In these situations, an alternative strategy must be pursued.

Focused on speed to therapy

 BD VeloCath™ IV Catheter allows clinicians to get vascular access quicker compared to the time it takes to perform a full central line procedure. Like a peripheral IV, this device requires fewer procedural steps than a traditional acute CVC, which means that this procedure is simpler, less invasive and allows the patient to receive therapy faster compared to an acute CVC.

Convenient kit options

We have basic, intermediate and max barrier access kits for use depending on the needs of the patient and the nature of the procedure.

A true utility device — Our Emergent Access Kit contains all of the components you may need to place, dress and secure this device in neck veins or peripherally.

Flow rates — The BD VeloCath™ IV Catheter is designed to deliver fluids rapidly, allowing up to 3,720 mL/hr.

Blood control

Air embolism is a potentially fatal complication associated with acute central line insertion procedures. The blood control valve is designed to reduce the risk of an air embolism.

Reference
  1. Data on file at BD, Salt Lake City, Ut
  2. Sau V, McManus C, Mifflin N, Frost SA, Ale J, Alexandrou EA. Clinical pathway for the management of difficult venous access. BMC Nurs. 2017; 16:1-7. Dol: 10.1186/s12912-017-0261-z 2018.0
true

Specifications

Product CodeProduct
AC1418220BD VeloCath™ 18 x 2.25 basic emergent access kit
AC1418222BD VeloCath™ 18 x 2.25 intermediate emergent access kit
AC1418221DBD VeloCath™ 18 x 2.25 max barrier emergent access kit
References
  1. Data on file at BD, Salt Lake City, Ut
  2. Sau V, McManus C, Mifflin N, Frost SA, Ale J, Alexandrou EA. Clinical pathway for the management of difficult venous access. BMC Nurs. 2017; 16:1-7. Dol: 10.1186/s12912-017-0261-z 2018.0
true

Component Chart

 BD VeloCath™ IV Catheter basic emergent access kitBD VeloCath™ IV Catheter intermediate emergent access kitBD VeloCath™ IV Catheter max barrier emergent access kit
BD VeloCath™ Intravascular Catheter, 18 G x 2.25 in
2 ChloraPrep™ Solution One-Step Applicators (tinted) 3 mL 
1 ChloraPrep™ Solution One-Step Applicators (tinted) 3 mL
Bordered transparent adhesive dressing
StatLock® Stabilization Device and skin prep pad
Surgical tape 
Alcohol prep pad 
2 in. x 2 in. gauze sponges (5 pieces) 
4 in. x 4 in. gauze sponges (10 pieces) 
Extension set (power injectable, microbore, 7 in.) 
Tourniquet 
48" (122 cm) probe cover, elastic bands, and conductive gel 
Intermediate fenestrated drape  
Max barrier fenestrated drape  
Bouffant cap  
Absorbent towel  
6 mL syringe  
Filter aspiration device for lidocaine  
2 Masks  
Gown  
Gloves  
25 G hypodermic needle  
Lidocaine HCI 1%, 5 mL ampule  
Sodium chloride syringe (saline) 0.9%, 10 mL  

 

Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
References
false
Resources
References
  1. Data on file at BD, Salt Lake City, Ut
  2. Sau V, McManus C, Mifflin N, Frost SA, Ale J, Alexandrou EA. Clinical pathway for the management of difficult venous access. BMC Nurs. 2017; 16:1-7. Dol: 10.1186/s12912-017-0261-z 2018.0
true
true