{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
Venovo™ Venous stents Venovo™ Venous Stent System

Venovo™ Venous Stent System

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon
Contact Us
Icon to close thank you modal
Thank you for contacting our sales team!
A sales representative will get in touch with you shortly.
Onsite Visiting
Location Icon
850 W. Rio Salado Parkway, Tempe, Arizona 85281 United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.440.5376
Overview

Venous disease is complex, your stent choice doesn't have to be

  • Engineered to provide the optimal balance between radial force, flexibility, and compression resistance
  • Tri-axial delivery system designed to provide accurate deployment to help facilitate optimal stent placement and lesion coverage
  • 3mm flared stent ends designed to reduce the risk of stent migration and maximize wall apposition
  • Broadest size matrix of iliofemoral-indicated venous stents in the U.S.1
    • Diameters up to 20 mm
    • Stent lengths up to 160 mm

 

 

true
Features and Benefits
Promotional Story
false
References

As of September 2022

2Radial resistive force was tested at 13 mm crimp diameter (1 mm oversizing) using a radial expansion force gauge. Results shown as averages measured in N/mm as follows (n=6): Venovo™ Venous Stent System (0.126), Medtronic Abre™ Venous Stent (0.1035), Cook Zilver® Vena™ (0.063) and Boston Scientific VICI VENOUS STENT® (0.054). Data on file. Bench tests may not be indicative of clinical performance. Different test methods may yield different results. 

3Foreshortening is calculated as the difference, represented as percentage, between the compressed stent length and expanded stent length at minimum/maximum oversize (1-3 mm). Across all sizes, foreshortening ranged from -4% to 10%, with a mean of 2.9% (values based on mathematical calculations). Data on file, BD Peripheral Intervention, Tempe, AZ.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, potential complications, adverse events and detailed safety information.

Venovo IFU

BD - 23533v3

true
Specification

GTIN - each

00801741103551

1


16 mm

40 mm

80 cm

0.035"

10F

GTIN

GTIN - each 00801741103551 1

16 mm
40 mm
80 cm
0.035"
10F
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false