Transform the care experience with longer-lasting peripheral IV catheters that enable needle-free blood draws1,2

The PIVO™ Pro Needle-free Blood Collection Device is designed to achieve the first and only compatibility with integrated and long peripheral IV catheters, including the new Nexiva™ Closed IV Catheter System with NearPort™ IV Access in addition to traditional short IV catheters.

BD is transforming clinical workflows and their outcomes1,2 by combining the proprietary technologies of closed IV catheter systems that have shown to improve dwell times and reduce complications with a needle-free blood collection device to overcome traditional IV and blood collection challenges.2

true
Features and Benefits
Promotional Story
false
References
  1. González López J, Arribi Vilela A, Fernández Del Palacio E, et al. Indwell times, complications and costs of open vs closed safety peripheral intravenous catheters:a randomized study. J Hosp Infect. 2014;86(2):117-126.
  2. Pendleton B, LaFaye R. Multicenter study of needle-free blood collection system for reducing specimen error and intravenous catheter replacement. J Healthc Qual. 2022;44(2):e24-e30. doi:10.1097/JHQ.0000000000000331.
  3. Helm RE, Klausner JD, Klemperer JD, et al. Accepted but unacceptable; peripheral IV catheter failure: Infus Nurs Society. 2015;38(3):189-203.
  4. Twibell KR, Hofstetter P, Siela D, Brown D, Jones HM. A comparative study of blood sampling from venipuncture and short peripheral catheters in pediatric inpatients. J Infus Nurs. 2019;42(5):239. doi:10.1097/NAN.0000000000000338.
  5. Green SF. The cost of poor blood specimen quality and errors in preanalytical processes. Clin Biochem. 2013;46:1175-1179. doi: 10.1016/j.clinbiochem.2013.06.001
  6. Mannocci A, De Carli G, Di Bari V, et al. How much do needlestick injuries cost? A systematic review of the economic evaluations of needlestick and sharps injuries among healthcare personnel. Infect Control Hosp Epidemiol. 2016;37(6):636-646. doi:10.1017/ice.2016.48.
  7. O'Malley C. The frequency and reasons for central line accesses in critical care units. Canadian Journal of Infection Control. 2018;33(3):165-167
  8. Adams S, Toroni B, Lele M. Effect of the PIVO device on the procedure of phlebotomy from peripheral IV catheters. Nurs Res Pract. 2018:7380527.  doi:10.1155/2018/7380527
  9. Goel D, Smitthimedhin A, Yadav B, et al. Ultrasound-detected venous changes associated with peripheral intravenous placement in children. JAVA. 2020;25(1)36-42.
  10. Natali R, Wand C,Doyle K, Noguez JH. Evaluation of a new venous catheter blood draw device and its impact on specimen hemolysis rates. Pract Lab Med. 2018;10:38-43. doi:10.1016/j.plabm.2018.01.002.
  11. Cadacio C, Nachamkin I. A novel needle-free blood draw device for sample collection from short peripheral catheters. JIN. 2017;40(3):156-162.
  12. Mulloy DF, Lee SM, Gregas M, Hoffman KE, Ashley SW. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response. Appl Nurs Res. 2018;40:76-79. doi:10.1016/j.apnr.2017.12.006.
  13. Bausone-Gazda D, Lefaiver CA, Walters SA. A randomized controlled trial to compare the complications of 2 peripheral intravenous catheter-stabilization systems. J Infus Nurs. 2010;33(6):371-384.
  14. Matthews EE. Sleep disturbances and fatigue in critically ill patients. AACN Adv Crit Care. 2011:22(3):204-224. doi:10.1097/NCI.0b013e31822052cb.
  15. Psaila J, Parsons TF, Hahn SA, Fichera L. Prospective study evaluating whether standard peripheral intravenous catheters can be used for blood collection throughout hospital stay. J Infus Nurs. 2023 Jan-Feb 01;46(1):43-47. doi: 10.1097/NAN.0000000000000493. PMID: 36571827; PMCID: PMC9831029.
  16. DuBose JR, Hadi K. Improving inpatient environments to support patient sleep. International Journal for Quality in Health Care. 2016;28950540-553 doi.1093/intqhc/mzw079.
  17. Mengistu, DA, Tolera ST, Demmu YM. Worldwide prevalence of occupational exposure to needle stick injury among healthcare workers: a systematic review and meta-analysis. Canadian Journal of Infectious Disease and Medical Microbiology. 2021.
  18. Van Loon FH, Timmerman R, den Brok GP, et al. The impact of a notched peripheral intravenous catheter on the first attempt success rate in hospitalized adults: Block-randomized trial. J Vasc Access. 2022;(2):295-303.
  19. Seetharam AM, Raju U, Suresh K. A randomized controlled study to compare first stick success with Instaflash technology: The FIRSST study. J Vasc Access. 2022:1297298221080369.
  20. Kuriakose L. Decreasing central line associated bloodstream infection through limiting the use of central venous catheters for routine blood draws. J Dr Nurs Pract. 2020:13(2):173-183.doi:10.1891/JDNP-D-19-00071
  21. McLenon J, Rogers MAM. The fear of needles: a systematic review and meta-analysis. J Adv. Nurs. 2019;75:30-42
  22. Sharma SK, Kant R, Kalra S, Bishnoi R. Prevalence of primary non-adherence with insulin and barriers to insulin initiation in patients with type 2 diabetes mellitus – An exploratory study in a tertiary care teaching public hospital. Eur Endocrinol. 2020:16(2):143-147. doi:10.17925/EE.2020.16.2.143
  23. Ibrahim I, Yau YW, Ong L, Chan YH, Kuan WS. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study. Acad Emerg Med. 2015;22(3):315-320. doi:10.1111/acem.12601
  24. Gill H, Prausnitz M. Does needle size matter? J Diabetes Sci Technol 2007;1(5):725-729

BD-66490 (10/23)

true
Specification

GTIN - Case

20850984007021

200

GTIN - Shelfpack

10850984007024

50

GTIN - each

00850984007027

1


DEHP is not part of the Material Formulation


Total Shelf Life

3 Years

Legal Manufacturer's Address

Velano Vascular, San Francisco, CA


Quantity - Each

1

Quantity - Box

50

Quantity - Case

200


Sterilization Method

Gamma

Length

Inner Tube Length 5.85 inches

Material

Inner Tube Material-Polyimide

Color

Pink

GTIN

GTIN - Case 20850984007021 200
GTIN - Shelfpack 10850984007024 50
GTIN - each 00850984007027 1

FDA, Premarket Approval, and Regulatory

DEHP is not part of the Material Formulation

Manufacturing

Total Shelf Life 3 Years
Legal Manufacturer's Address Velano Vascular, San Francisco, CA

Packaging

Quantity - Each 1
Quantity - Box 50
Quantity - Case 200

Product Basic Specification

Sterilization Method Gamma
Length Inner Tube Length 5.85 inches
Material Inner Tube Material-Polyimide
Color Pink
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions

The PIVO™ Pro Needle-free Blood Collection Device advances a flexible flow tube through the IV catheter to access optimal blood draw conditions, overcoming traditional hurdles to collect high-quality, reliable blood samples.11

The PIVO™ Pro Blood Collection Device has been shown in clinical and healthy human studies to provide reliable, high-quality blood draws from peripheral IV catheter lines.*,2 In addition to providing high-quality blood draws with low rates of hemolysis, the PIVO™ Pro Blood Collection Device may have a positive impact on patient experience by reducing repetitive needlesticks and redraws that may result in care delays.12

The BD Peripheral Line Draw Solution is fully compatible with the BD portfolio of blood collection products and peripheral IV catheters, including BD Vacutainer® Luer-Lok™ Access Device, BD Vacutainer® Blood Collection Tubes, Nexiva™ Closed Catheter System with NearPortTM IV Access, AccuCath Ace™ Intravascular Catheter as well as the BD Insyte™ Autoguard™ Safety IV Catheter and BD Cathena™ Safety IV Catheter portfolio of products.

The PIVO™ Pro  Blood Collection Device provides compassionate care that alleviates fear and anxiety associated with repetitive needlesticks by reducing IV replacement2,13 and using existing access for blood draws11 with minimal disruption to a patient's sleep and healing process.14-16

Compared with venipuncture, patients who received daily phlebotomy collections rated their overall experience a 9.1 out of 10 using the PIVO™ Blood Collection Device.13

The BD Peripheral Line Draw Solution includes the PIVO™ Pro Blood Collection Device and Nexiva™ Closed IV Catheter System with NearPort™ IV Access. Together these products help to reduce the number of sticks associated with venipuncture and IV replacement2 helping to preserve vessel health for future access.4 Reliable peripheral line draws may also provide an alternative to the reliance and associated risks of central line draws.19

Streamline clinical workflow with a innovative line draw solution that optimizes IV performance to effectively perform reliable blood draws and reduce IV replacements, empowering clinician confidence at each patient encounter.2,5

Performing a needle-free blood draw and reducing the number of sticks associated with sample recollections and IV replacements reduces the potential risk of an accidental needlestick injury.2

It preserves your patient’s vessel health4 by maximizing first stick success,18 minimizing IV replacements, and using existing access for blood draws.2,11

Needle phobia terminology differs throughout literature and includes terms that are often used interchangeably: scared of needles, fear of needles, needle fear, Blood-Injection Injury (BII) phobia, fear of injections, and needle anxiety.

If your patients have needle phobia, it could lead to avoidance behavior. This includes exacerbated avoidance of treatment, blood donations, and vaccinations – all which can negatively impact patient care.20,21

The most common device-related approach for addressing needle phobia is utilizing innovations that include smaller/thinner needles, followed by needle-free options.22,23

*Clinical studies were done on previous generations of the PIVO™ Blood Collection Device and Nexiva™ Catheter System. PIVO™ Pro and Nexiva™ with NearPort IV Access are the next generations of their respective product families.

true
References
false
Alternatives Comparison
  • Alternatives Comparison

    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
    • Product Name
    • SKU Number
    • Quantity - Case
    • Quantity - Each
    • Sterilization Method
    • DEHP is not part of the Material Formulation
    • Length
    • Color
    • Quantity - Box
    • Total Shelf Life
    • Material
    • Legal Manufacturer's Address
  • Product Image
    • Product Name

      PIVO™ Needle-free Blood Collection Device
    • SKU Number

      202-0005
    • Quantity - Case

      200
    • Quantity - Each

      1
    • Sterilization Method

      Gamma
    • DEHP is not part of the Material Formulation

    • Length

      Inner Tube Length 5.85 inches
    • Color

      Pink
    • Quantity - Box

      50
    • Total Shelf Life

      3 Years
    • Material

      Inner Tube Material-Polyimide
    • Legal Manufacturer's Address

      Velano Vascular, San Francisco, CA
  • Product Image
    • Product Name

      PIVO™ Needle-free Blood Collection Device
    • SKU Number

      202-0006
    • Quantity - Case

      200
    • Quantity - Each

      1
    • Sterilization Method

      Gamma
    • DEHP is not part of the Material Formulation

    • Length

      Inner Tube Length 5.85 inches
    • Color

      Blue
    • Quantity - Box

      50
    • Total Shelf Life

      3 Years
    • Material

      Inner Tube Material-Polyimide
    • Legal Manufacturer's Address

      Velano Vascular, San Francisco, CA
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false